- Plugs directly into main TDR unit via two 4 mm safety plugs on 19mm center
- 600 volt cat 1V rated
- 50 cm long output leads
- Complete with fused test clips
Warning: Trying to access array offset on false in /home/sites/3b/3/334cb94cd0/public_html/wp-content/plugins/catalog-for-woocommerce/mainplugin.php on line 110
Accessories & Cables, Power Networks Test
Blocking Filter
This blocking filter has been designed for use with the BI Communications TX Range of Time-Domain Reflectometers. When used with the TDR, it will allow the testing of powered cables up to a maximum of 600V CAT IV.
This device meets the requirements of EN61010-1-2010.
Safe operation cannot be guaranteed if the device is used without observing all safety conditions. The operator or user will be liable to damage to persons or property resulting from incorrect use.
Detail Spec
Rated Voltage Up to 600V CAT IV
Rated Frequency 50/60 Hz
Operating Temperature -10◦C (min) to 50◦C (max)
Storage Temperature -20◦C (min) to 70◦C (max)
Dimensions 28.5 x 85 x 50 (mm)
Weight 200g
Cable Length 0.5m
Safety EN 61010-1-2010
Water/Dustproof IP54
Fuse Rating 1000V, 500mA Quick Blow (6.3×32 mm)